DocumentCode :
1605364
Title :
Impulse Line Blocking Diagnosis of Digital differential pressure transmitter
Author :
Yuki, Yoshitaka ; Kuromori, Kenichi ; Miyaji, Nobuo ; Hashizume, Takumi ; Eino, Jyun-ichi ; Wakui, Tetsuya
Author_Institution :
Yokogawa Electr. Corp., Musashino-Shi
fYear :
2006
Firstpage :
4698
Lastpage :
4702
Abstract :
Differential pressure transmitter with an orifice has achieved great field performance and success in flow measurement as a reliable field flow meter. However, blockage in impulse line attached to transmitter is sometime caused by precipitating or solidifying liquids. The pressure signals have random fluctuation signals due to a turbulent flow in a pipeline, and in case of impulse line blockage, the fluctuation signals vary from that of normal conditions. Mean square of differential pressure fluctuation has formerly been used to evaluate the blocking state. However, mean square of differential pressure fluctuation is strongly affected by flow rate. Then we have developed a new diagnostic technique, in which a specific parameter F called ´blockage factor´ indicates the extent of each impulse line blockage. Dp transmitter EJX series is able to measure not only the differential pressure but also the static pressure at high and low pressure sides of orifice by means of silicon resonant pressure sensor. EJX makes it possible to calculate statistical variables F by using three pressure signals. We confirmed that blockage can be detected by using statistical variables F. Thus, impulse line blocking diagnosis of digital differential pressure transmitter contributes to predicting blockage in impulse line and saving maintenance cost
Keywords :
flow measurement; flow simulation; flowmeters; fluctuations; pipe flow; pressure sensors; random processes; turbulence; Dp transmitter; EJX series; blockage factor; diagnostic technique; differential pressure fluctuation; digital differential pressure transmitter; field flow meter; flow measurement; flow rate; high pressure side; impulse line blocking diagnosis; liquid solidification; low pressure side; orifice; pipeline; precipitation; pressure signals; random fluctuation signals; silicon resonant pressure sensor; static pressure; statistical variables; turbulent flow; Costs; Fluctuations; Fluid flow measurement; Liquids; Orifices; Pipelines; Pressure measurement; Resonance; Silicon; Transmitters; blockage factor; diagnosis; digital differential pressure transmitter; impulse line blockage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
SICE-ICASE, 2006. International Joint Conference
Conference_Location :
Busan
Print_ISBN :
89-950038-4-7
Electronic_ISBN :
89-950038-5-5
Type :
conf
DOI :
10.1109/SICE.2006.314732
Filename :
4108509
Link To Document :
بازگشت