• DocumentCode
    1606041
  • Title

    Two Dimensional Stress Reproduction Using Ultrasound Tactile Display

  • Author

    Iwamoto, Takayuki ; Shinoda, Hiroyuki

  • Author_Institution
    Graduate Sch. of Inf. Sci. & Technol., Tokyo Univ.
  • fYear
    2006
  • Firstpage
    4818
  • Lastpage
    4821
  • Abstract
    We proposed a new tactile display which produces spatio-temporal stress patterns on a 2D plane. In this paper, the first prototype is reported. The display consists of eight ultrasound linear arrays arranged so that the PZT pieces were concentric octagons. In order to produce 2D spatio-temporal stress patterns, the focal point of ultrasound was scanned over the display surface. We measured the waveform of the sound pressure at the focal point and the spatial distribution of the radiation pressure around the focal point. The data showed that the temporal and spatial property of the display were sufficiently fine for our method for producing 2D spatio-temporal stress patterns
  • Keywords
    tactile sensors; ultrasonic transducer arrays; 2D spatio-temporal stress pattern reproduction; acoustic radiation pressure; spatial distribution; ultrasound linear arrays; ultrasound tactile display; Actuators; Humans; Nonlinear acoustics; Optical films; Prototypes; Skin; Stress; Two dimensional displays; Ultrasonic imaging; Ultrasonic variables measurement; acoustic radiation pressure; tactile display; ultrasound;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    SICE-ICASE, 2006. International Joint Conference
  • Conference_Location
    Busan
  • Print_ISBN
    89-950038-4-7
  • Electronic_ISBN
    89-950038-5-5
  • Type

    conf

  • DOI
    10.1109/SICE.2006.314975
  • Filename
    4108532