DocumentCode :
1606331
Title :
Thermal analysis of the ITER TF Feeder cryogenic components
Author :
Erwu Niu ; Zhongwei Wang ; Guang Shen ; Shanwen Zhang
Author_Institution :
ITER China, Beijing, China
fYear :
2013
Firstpage :
1
Lastpage :
5
Abstract :
The TF Feeder delivers electricity and coolant to the superconducting TF coil, the superconducting busbar and supercritical helium pipe are all work at 4K. Without proper thermal insulation designs, the heat load from room environment will make it impossible to keep the busbar and the coil superconducting, thus numerous and accurate thermal analyses are performed to verify the design. It is vacuum inside the Feeder chambers, and the heat load mainly comes from the support conduction and the thermal radiation; 80K thermal shield, thermal intercept and low thermal conductivity support material are employed to minimize the heat load. Since the Feeder is a huge structure over 10m in length, it costs time for it to be cooled down, there must be a delay compared to the active cooled TF coils. Therefore, the cool down time is also researched in this paper.
Keywords :
cryogenics; fusion reactor reaction chamber; superconducting coils; thermal analysis; thermal conductivity; Feeder chambers; ITER TF Feeder cryogenic components; accurate thermal analyses; coil superconducting; heat load; superconducting TF coil; superconducting busbar; supercritical helium pipe; thermal analysis; thermal conductivity; thermal insulation designs; thermal intercept; thermal radiation; thermal shield; Coils; Cryogenics; Ducts; Heating; Thermal analysis; Thermal conductivity; Thermal loading; Feeder; cryogenic; thermal analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Fusion Engineering (SOFE), 2013 IEEE 25th Symposium on
Conference_Location :
San Francisco, CA
Print_ISBN :
978-1-4799-0169-2
Type :
conf
DOI :
10.1109/SOFE.2013.6635399
Filename :
6635399
Link To Document :
بازگشت