Abstract
An effective and simple algorithm for localization of abnormal sources of the EEG signals within the brain has been developed here. In this method the signals are separated first, then the estimated independent components are lowpass filtered and normalized. In the next stage the correlation values between the estimated sources and the electrode signals are measured. On the other hand the sources with known locations are separated offline using narrowband bandpass filters. Finally, as the main contribution of the paper the mixing matrix is estimated using the information about the known sources and the estimated sources. The locations of the unknown sources are then measured with respect to the columns of the mixing matrix and the geometrical properties of the head and electrode locations
Keywords
band-pass filters; biomedical electrodes; blind source separation; electroencephalography; independent component analysis; low-pass filters; medical signal processing; EEG; blind source separation; brain abnormal signal source localization; electrode signals; independent components; lowpass filter; mixing matrix; narrowband bandpass filters; normalization; Band pass filters; Blind source separation; Direction of arrival estimation; Electrodes; Electroencephalography; Epilepsy; Rhythm; Signal processing; Signal processing algorithms; Working environment noise;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location
Shanghai
Print_ISBN
0-7803-8741-4
Type
conf
DOI
10.1109/IEMBS.2005.1616631
Filename
1616631
Link To Document