DocumentCode :
1607181
Title :
Validity of Polygraphs
Author :
Suryanarayanan, Prashant ; Kumar, Dinesh K. ; Burton, Peter
fYear :
2005
fDate :
6/27/1905 12:00:00 AM
Firstpage :
1200
Lastpage :
1203
Abstract :
Electrodermal activity is extensively used for measuring human emotions. Validity and reliability have been questioned by some researchers. This paper reports on highly controlled experiments to determine the validity of electrodermal activity for measuring human emotions. The authors were unable to determine the validity of electrodermal activity for measuring human emotions. Inter and intra subject variation was very high
Keywords :
bioelectric phenomena; emotion recognition; health care; skin; electrodermal activity; human emotions; polygraphs; validity; Anthropometry; Cardiology; Current measurement; Electrical resistance measurement; Electronic design automation and methodology; Humans; Occupational stress; Psychology; Skin; Thyristors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1616639
Filename :
1616639
Link To Document :
بازگشت