• DocumentCode
    1607875
  • Title

    Thick film resistor testing by electro — Ultrasonic spectroscopy with DC electric signal

  • Author

    Pavel, Tofel ; Vlasta, Sedlakova ; Josef, Sikula

  • Author_Institution
    Dept. of Phys., Univ. of Technol., Brno, Czech Republic
  • fYear
    2008
  • Firstpage
    73
  • Lastpage
    76
  • Abstract
    The new method of non-destructive testing of the thick film resistors is presented. There are two phenomena which lead to the resistance modulation: (i) The interaction of the charge carriers with phonons, (ii) The ultrasonic signal changes the contact area between the conducting grains in the resistor structure. Ultrasound-excited resistance change in polymer based thick film structures is about 0.005 Omega to 1 Omega, which corresponds to the relative resistance change of the order from 10-6. We suppose that the resistive structures with defects are more influenced by the ultrasonic vibrations. The intermodulation signal can be used as the quality and reliability indicator.
  • Keywords
    phonons; thick film resistors; ultrasonic materials testing; DC electric signal; charge carrier; electro-ultrasonic spectroscopy; nondestructive testing; ntermodulation signal; phonon; polymer based thick film structure; resistance modulation; thick film resistor; ultrasonic vibration; Charge carriers; Contact resistance; Electric resistance; Nondestructive testing; Phonons; Polymer films; Resistors; Spectroscopy; Thick films; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics Technology, 2008. ISSE '08. 31st International Spring Seminar on
  • Conference_Location
    Budapest
  • Print_ISBN
    978-1-4244-3972-0
  • Electronic_ISBN
    978-1-4244-3974-4
  • Type

    conf

  • DOI
    10.1109/ISSE.2008.5276457
  • Filename
    5276457