• DocumentCode
    1608661
  • Title

    Improved partial k-space reconstruction technique for dynamic myocardial perfusion MRI

  • Author

    Vijayakumar, Sathya ; Huang, Feng ; DiBella, Edward V R

  • Author_Institution
    Res. & Pre-Development, Invivo Diagnostic Imaging, Gainesville, FL
  • fYear
    2006
  • Firstpage
    1419
  • Lastpage
    1421
  • Abstract
    The advent of partially parallel k-space data acquisition and reconstruction techniques has resulted in a drastic reduction in acquisition time. In this work, we have shown that the use of a new hybrid technique for reconstruction of partial k-space data can reduce acquisition time without loss of spatiotemporal resolution. The technique is termed hybrid k-t GRAPPA since it is a combination of k-t GRAPPA and an image-k-space keyhole technique. The hybrid method with an acceleration factor 4 generated better results than standard GRAPPA with acceleration factor 2 in preliminary results
  • Keywords
    biomedical MRI; data acquisition; haemorheology; image reconstruction; image resolution; medical image processing; spatiotemporal phenomena; dynamic myocardial perfusion MRI; hybrid k-t GRAPPA; image-k-space keyhole technique; partial k-space reconstruction; partially parallel k-space data acquisition; spatiotemporal resolution; Acceleration; Arteries; Data acquisition; Hybrid power systems; Image generation; Image reconstruction; Image resolution; Magnetic resonance imaging; Myocardium; Spatiotemporal phenomena; Partially parallel imaging techniques; and tracer kinetic model; hybrid k-t GRAPPA; k-t GRAPPA; myocardial perfusion MRI;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
  • Conference_Location
    Shanghai
  • Print_ISBN
    0-7803-8741-4
  • Type

    conf

  • DOI
    10.1109/IEMBS.2005.1616696
  • Filename
    1616696