DocumentCode
1609131
Title
The Investigations of Influence of Isotropic Coupling Between Ferrite Coupled Slot-Lines on Parameters of FCSL Circulator
Author
Kusiek, Adam ; Marynowski, Wojciech ; Mazur, Jerzy
Author_Institution
Gdansk Univ. of Technol., Gdansk
fYear
2006
Firstpage
651
Lastpage
654
Abstract
The investigations of ferrite coupled slot-line circulator (FCSL) with longitudinal magnetization are presented. The influence of isotropic coupling between slot-lines of ferrite section on S-parameters of the circulator is reported. The simulated results shows that decreasing isotropic coupling in FCSL allow to achieve better parameters of designed circulator and reduce its dimensions. One of the investigated configuration of circulator is measured and promising results for its design are achieved.
Keywords
S-parameters; ferrite circulators; magnetisation; slot lines; ferrite coupled slot-line circulator; isotropic coupling; longitudinal magnetization; s-parameter; Bandwidth; Couplings; Dielectric substrates; Ferrites; Geometry; Insertion loss; Magnetization; Microstrip; Scattering parameters; Slabs;
fLanguage
English
Publisher
ieee
Conference_Titel
Microwaves, Radar & Wireless Communications, 2006. MIKON 2006. International Conference on
Conference_Location
Krakow
Print_ISBN
978-83-906662-7-3
Type
conf
DOI
10.1109/MIKON.2006.4345264
Filename
4345264
Link To Document