Abstract :
An electronically controlled SCR-based, medium voltage starter was used to limit the starting current and ramp up to speed a 2250 hp, 4160 V induction motor used to cut coke in a delayed coker unit. The electronic starter application is outlined from the standpoint of selection, installation, operation and analysis of economic and reliability benefits. A description of this application and the historical reliability problems are described in detail
Keywords :
cutting; induction motors; jets; mineral processing industry; starting; thyristor applications; 2250 hp; 4160 V; MV electronic starter; SCR; application; delayed coke process water jet cutting pump; induction motor starting; installation; reliability; selection; Automation; Cogeneration; Consumer electronics; Costs; Delay; Fuel economy; Induction motors; Maintenance; Valves; Water jet cutting;