DocumentCode :
1610944
Title :
Diagnostic characteristics of axial flux in an induction machine
Author :
Jarzyna, W.
Author_Institution :
Dept. of Electr. Drive Syst., Lublin Tech. Univ., Poland
fYear :
1995
Firstpage :
141
Lastpage :
146
Abstract :
Axial flux in an induction machine is formed as a result of asymmetry of electric and magnetic circuits. In the paper particular attention is focused on determining an influence of nonsymmetrical air-gap on the flux spectrum. An improved method of frequency analysis is discussed. This method consists of taking into account only the most essential factors having an effect on the value and characteristics of axial flux. In the presented description, only two the lowest harmonics of air-gap permeance are taken into account. They create together with the fundamental harmonic of the field, supplementary electromagnetic couplings. Knowledge of these couplings makes it possible to distinguish frequency lines that occur as a result of static rotor eccentricity. Chosen test results are presented and certain problems concerning realisation of a diagnostic system are mentioned
Keywords :
air gaps; induction motors; machine theory; magnetic flux; rotors; air-gap permeance; axial flux; diagnostic characteristics; diagnostic system; electric circuit; electromagnetic couplings; flux spectrum; frequency analysis; harmonics; induction machine; induction motor; magnetic circuit; nonsymmetrical air-gap; static rotor eccentricity;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Electrical Machines and Drives, 1995. Seventh International Conference on (Conf. Publ. No. 412)
Conference_Location :
Durham
Print_ISBN :
0-85296-648-2
Type :
conf
DOI :
10.1049/cp:19950851
Filename :
497712