DocumentCode :
1610961
Title :
An Effective Image Measurement in Brachial Flow-Mediated Dilation Response Analysis
Author :
Chien, Jen-Chien ; Wang, Jeng-Pang ; Hsueh, Meng-Lun ; Cheng, Po-Shuen ; Chong, Fok-Ching
Author_Institution :
Inst. of Electr. Eng., Nat. Taiwan Univ., Taipei
fYear :
2006
Firstpage :
1750
Lastpage :
1753
Abstract :
Non-invasive cardiovascular measurements are used to evaluate cardiovascular diseases early and to cure early. By using various evaluation methods of cardiovascular features to diagnose cardiovascular disease. Flow-mediated dilation (FMD) evaluated by ultrasound offers a mechanism to characterize endothelial function and, therefore, may play a role in the diagnosis of cardiovascular diseases. Cardiovascular endothelial is intermedia between blood and cardiovascular muscle. It has important effect for keeping balance of the environment in vessel. Nitric oxide (NO) is the most important fact. Many cardiovascular diseases, like high cholesterol, high blood pressure, coronary heart disease, diabetes, smoking, is the cause of endothelial dysfunction. We design a series of images analysis methods to compute the change of cardiovascular radius in ultrasound images for evaluating endothelial function instead of measuring by-hand. We use B-mode ultrasound system to measure brachial cardiovascular radius. Then we capture the images by image capture card 10 images per second. We evaluate the average radius of brachial cardiovascular radius before we cut off blood flow. And we evaluate the maximum radius of brachial cardiovascular radius after we cut off blood flow and release it. Using the two radii we can compute the FMD value to evaluate endothelial function. First, we use Hough transform to detect possible center possible of vessel. Then we use edge-reserved filter to filtrate speckle noise and preserve edge. After filtrating noise, we utilize Laplacian of Gaussian to detect edge-points. Finally, we use gradient-based Hough transform to determine the center position, major axis, minor axis, and angle of evaluated ellipse. We use radius of the circle witch has equal area with the evaluated ellipse to be our final result. We measure the FMD value for 8 people (age from 23 to 26 years old). Comparing the result measured by our design system with by hand, the accuracy is 96.31%
Keywords :
Gaussian processes; Hough transforms; biomedical ultrasonics; blood vessels; cardiovascular system; diseases; haemodynamics; medical image processing; nitrogen compounds; B-mode ultrasound system; Gaussian method; Laplacian method; blood flow; brachial cardiovascular radius; brachial flow-mediated dilation response analysis; cardiovascular disease diagnosis; center position; coronary heart disease; diabetes; edge preservation; edge-point detection; edge-reserved filter; endothelial dysfunction; endothelial function; gradient-based Hough transform; high blood pressure; high cholesterol; image measurement; images analysis; major axis; minor axis; nitric oxide; noninvasive cardiovascular measurements; smoking; speckle noise filtering; ultrasound images; vessel; Blood flow; Blood pressure; Brachytherapy; Cardiology; Cardiovascular diseases; Image analysis; Image edge detection; Muscles; Ultrasonic imaging; Ultrasonic variables measurement; FMD; Flow-mediated dilation; Hough Transform; edge-reserved filter; gradient-based Hough Transform; speckle noise;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the
Conference_Location :
Shanghai
Print_ISBN :
0-7803-8741-4
Type :
conf
DOI :
10.1109/IEMBS.2005.1616784
Filename :
1616784
Link To Document :