DocumentCode
1613092
Title
Signal conditioner for piezoelectric sensors
Author
Blejan, Marian ; Ilie, Ioana ; Lupu, Bogdan ; Comes, Mircea
Author_Institution
Servotechnics & Electron. Dept., INOE, Bucharest, Romania
fYear
2008
Firstpage
343
Lastpage
347
Abstract
This paper presents a new constructive solution for the signal conditioner of piezoelectric sensors. Piezoelectric sensors have proven to be versatile tools for the measurement of various processes. They are used for quality assurance, process control and process development in many different industries. Such field is represented by the hydraulic powered actuators, where the system must be capable to work in severe exploiting conditions. The proposed signal conditioner includes a MCP602 operational amplifier made by Microchipreg. MCP602 has an input bias current of pA that allows direct connection between piezoelectric sensor and amplifier.
Keywords
hydraulic actuators; operational amplifiers; piezoelectric actuators; quality assurance; signal processing equipment; MCP602 operational amplifier; Microchip; hydraulic powered actuators; piezoelectric amplifier; piezoelectric sensors; process control; process development; quality assurance; signal conditioner; Circuits; Electromechanical sensors; Manufacturing processes; Master-slave; Mechanical sensors; Operational amplifiers; Sensor phenomena and characterization; Sensor systems; Signal processing; Temperature sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronics Technology, 2008. ISSE '08. 31st International Spring Seminar on
Conference_Location
Budapest
Print_ISBN
978-1-4244-3972-0
Electronic_ISBN
978-1-4244-3974-4
Type
conf
DOI
10.1109/ISSE.2008.5276665
Filename
5276665
Link To Document