Title :
Quantitative X-Ray Imaging of Density Distributions in High-Intensity Discharge Lamps
Author :
Curry, John J. ; Lafitte, Bruno
Author_Institution :
Nat. Inst. of Standards & Technol., Gaithersburg
Abstract :
Summary form only given. Development of a table-top X-ray absorption imaging apparatus for determination of Hg densities in high-intensity discharge lamps is described. The apparatus is based on a commercial X-ray tube source and detection of X-rays with a phosphor and optical charge-coupled device (CCD). This type of system has the apparent disadvantages, relative to a synchrotron based system, of lower X-ray flux and a broad spectrum. However, this system has better sensitivity. The reasons for this and a comparison of noise in both types of measurements are given. The ultimate sensitivity, the relation between X-ray photons and detector counts, and the implications of the broad X-ray spectrum on measurement accuracy are discussed.
Keywords :
X-ray absorption spectra; discharge lamps; discharges (electric); mercury (metal); plasma density; plasma diagnostics; Hg; Hg density distributions; X-ray absorption imaging; X-ray photons; X-ray tube source; detector counts; high-intensity discharge lamps; optical charge-coupled device; phosphor; sensitivity; Electromagnetic wave absorption; Fault location; High intensity discharge lamps; Mercury (metals); Optical devices; Optical imaging; Optical noise; X-ray detection; X-ray detectors; X-ray imaging;
Conference_Titel :
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0915-0
DOI :
10.1109/PPPS.2007.4345457