Title :
Cygnus Diverter Switch Analysis
Author :
Ormond, Eugene C. ; Nelson, Daniel S. ; Cordova, Steve R. ; Molina, Isidro ; Smith, John R. ; Corrow, George D. ; Hansen, Mark D. ; Henderson, David J. ; Mitton, Charles V.
Author_Institution :
Sandia Nat. Lab., Albuquerque
Abstract :
Summary form only given. The Cygnus Dual Beam Radiographic Facility consists of two 2.25-MV, 60-kA, 50-ns X-ray sources fielded in an underground laboratory at the Nevada Test Site. The tests performed in this laboratory invoke study of the dynamic properties of plutonium and are called subcritical experiments, from end-to-end. the Cygnus machines utilize the following components: Marx generator, water-filled pulse-forming line (PFL), water-filled coaxial transmission line, 3-cell inductive voltage adder (IVA), and rod-pinch diode. The upstream coaxial transmission line interface to the PFL is via a radial insulator with coaxial geometry. The downstream coaxial transmission line terminates in a manifold where the center conductor splits into three lines which individually connect to each of the IVA cell inputs. There is an impedance mismatch at this juncture. It is a concern that a reflected pulse due to anomalous behavior in the IVA or diode might initiate breakdown upon arrival at the upstream PFL/coax insulator. Therefore near the beginning of the coaxial transmission line a radial diverter switch is installed to protect the insulator from over voltage and breakdown. The diverter has adjustable gap spacing, and an in-line aqueous-solution (sodium thiosulfate) resistor array for energy dissipation. There are capacitive voltage probes at both ends of the coaxial transmission line and on the diverter switch. These voltage signals will be analyzed to determine diverter performance. Using this analysis the usefulness of the diverter switch is evaluated.
Keywords :
X-ray production; fusion reactor divertors; pulse generators; pulsed power supplies; pulsed power switches; radiography; 3-cell inductive voltage adder; Cygnus Dual Beam Radiographic Facility; Cygnus diverter switch analysis; Marx generator; Nevada Test Site; X-ray sources; capacitive voltage probe; current 60 kA; impedance mismatch; in-line aqueous-solution resistor array; plutonium; rod-pinch diode; time 50 ns; underground laboratory; upstream PFL/coax insulator; voltage 2.25 MV; water-filled coaxial transmission line; water-filled pulse-forming line; Coaxial components; Diodes; Insulation; Laboratories; Performance evaluation; Radiography; Switches; Testing; Transmission lines; Voltage;
Conference_Titel :
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0915-0
DOI :
10.1109/PPPS.2007.4345499