DocumentCode
1614569
Title
Factory test for development of energy storage system
Author
Lee, Han-Min ; Oh, Seh-Chan ; Lee, Chang-Mu ; Kim, Gil-Dong
Author_Institution
Korea Railroad Res. Inst., Adv. EMU Res. Team, Seoul
fYear
2008
Firstpage
1495
Lastpage
1498
Abstract
The ESS is able to store and discharge energy extremely quickly, consequently enabling a complete exchange of energy between vehicles, even if they are not braking and accelerating at precisely the same time, as is most frequently the case in everyday service. The ESS reduces primary energy consumption without affecting transport capacity and punctuality. In addition, the ESS can stabilize the system voltage. The ESS is considered to be one of the useful devices for energy storing and recycling. This paper presents the factory test of the ESS. Characteristics with/without the ESS are also presented for comparison. The verification test in a factory focused on stabilizing voltage. The catenary voltage with the ESS did not drop. But The voltage without ESS is fluctuated. The overhead voltage is compensated.
Keywords
electric vehicles; energy storage; regenerative braking; energy recycling; energy storage system; primary energy consumption; voltage stabilization; Acceleration; Electronic switching systems; Energy storage; Production facilities; Rail transportation; Recycling; Substations; System testing; Vehicles; Voltage; Energy storage system; energy saving; voltage stabilization;
fLanguage
English
Publisher
ieee
Conference_Titel
Control, Automation and Systems, 2008. ICCAS 2008. International Conference on
Conference_Location
Seoul
Print_ISBN
978-89-950038-9-3
Electronic_ISBN
978-89-93215-01-4
Type
conf
DOI
10.1109/ICCAS.2008.4694379
Filename
4694379
Link To Document