• DocumentCode
    1615536
  • Title

    Inner defect detection for a thin steel strip

  • Author

    Kim, Goohwa ; Choi, Sang-Woo ; Bae, Jinsu ; Kim, Jung-Hwan

  • Author_Institution
    Tech. Res. Lab., POSCO, Pohang
  • fYear
    2008
  • Firstpage
    1957
  • Lastpage
    1960
  • Abstract
    Two detection methods, magnetic and ultrasonic method, were compared to detect a defect that is located in and on the steel strip. The main composition of that defect is non-metallic oxides. We can select a proper method of detection according to the purpose of detector installation, the strip thickness, and the line speed. Magnetic flux leakage method is one of the promising methods for a very thin steel strip. On the other hand, the guided ultrasonic wave is very useful on for the thin steel strip such as the strip in pickling line.
  • Keywords
    magnetic flux; pickling (materials processing); steel industry; strips; ultrasonic applications; detector installation; guided ultrasonic wave; inner defect detection; magnetic flux leakage method; magnetic method; nonmetallic oxides; pickling line; thin steel strip; ultrasonic method; Eddy currents; Inspection; Magnetic flux leakage; Magnetic sensors; Metals industry; Optical surface waves; Radiography; Steel; Strips; Surface cracks; Inner defect detection; Magnetic; Steel strip; Ultrasonic;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control, Automation and Systems, 2008. ICCAS 2008. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-950038-9-3
  • Electronic_ISBN
    978-89-93215-01-4
  • Type

    conf

  • DOI
    10.1109/ICCAS.2008.4694418
  • Filename
    4694418