• DocumentCode
    1616655
  • Title

    Sloshing analysis using ground experimental apparatus

  • Author

    Oh, Choong-Seok ; Sun, Byung-Chan ; Park, Yong-Kyu ; Roh, Woong-Rae

  • Author_Institution
    Mission Design Dept., KARI, Daejeon
  • fYear
    2008
  • Firstpage
    2203
  • Lastpage
    2207
  • Abstract
    The natural frequencies and damping ratio of the liquid in cylindrical tank and cylindrical tank with spherical bottom are studied. The experimental frequencies and damping ratio are in good agreement with the results of the theoretical calculations for various liquid depths. Furthermore, this result will be applied to predict the sloshing parameters for a liquid propellant stage of KSLV-II using ground experimental apparatus.
  • Keywords
    confined flow; damping; fluid oscillations; sloshing; tanks (containers); KSLV-II; cylindrical tank; damping ratio; ground experimental apparatus; natural frequencies; sloshing analysis; spherical bottom; Assembly; Control systems; DC motors; Damping; Force sensors; Frequency; Propulsion; Signal analysis; Testing; Torque; Experimental apparatus; Slosh; Slosh damping; Slosh frequency;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control, Automation and Systems, 2008. ICCAS 2008. International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    978-89-950038-9-3
  • Electronic_ISBN
    978-89-93215-01-4
  • Type

    conf

  • DOI
    10.1109/ICCAS.2008.4694465
  • Filename
    4694465