Title :
B-dot Detector Signal Recording at the DARHT II Accelerator
Author :
Johnson, Jeffrey B. ; Ekdahl, Carl A. ; Broste, William B.
Author_Institution :
Los Alamos Nat. Lab., Los Alamos
Abstract :
Summary form only given. Diagnostic detectors such as B-dot and E-dot probes have been used in pulse power and accelerator applications for decades. The DARHT II Accelerator utilizes arrays of B-dot detectors as a means to determine beam current and position. Unique problems arise when using digital recording to capture these signal waveforms. Bit error and baseline reference stability in the recording devices limits the accuracy of the recorded waveform when dealing with fast rise time signals that have relatively long pulse widths. The reasons for methods used to record the B-dot data for the 2 microsecond duration beam current at DARHT II are detailed in this paper.
Keywords :
linear accelerators; particle beam diagnostics; B-DOT detector signal recording; DARHT II accelerator; beam current; beam position; Acceleration; Detectors; Digital recording; Laboratories; Particle beams; Probes; Sensor arrays; Signal detection; Stability; USA Councils;
Conference_Titel :
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0915-0
DOI :
10.1109/PPPS.2007.4345677