Title :
Power module integrated cooling design using CFD simulation
Author :
Karim, O. ; Schaeffer, C. ; Mallet, B. ; Coyaud, M. ; Gimet, E.
Author_Institution :
Lab. d´´Electrotech. de Grenoble, CNRS, Grenoble, France
Abstract :
Thermal grease used in classical power module water-cooling takes 40 percent of the water-cooled heat sink thermal resistance. This part which belong to conduction phenomena can be suppressed using a direct cooling method. In this paper, the basic conduction term provided by the component packaging is firstly determined, using several methods. Then mini water-cooled channels are directly machined in a standard power module baseplate, taking into account mechanical and technological constraints. In the same way a CFD tool, FLOTHERM from Flomerics is used in order to improve equipment performances such as a low junction to ambient thermal resistance, that approaches the power module´s own thermal resistance, a low pressure drop, a high dissipated power and a low gradient in coolant temperature. The equipment thermal and electrical behaviors are finally compared to a typical equipment including a power module and a cooling device mounted with thermal grease utilisation.
Keywords :
circuit CAD; computational fluid dynamics; cooling; integrated circuit design; modules; power integrated circuits; thermal analysis; thermal resistance; CFD simulation; FLOTHERM; direct cooling method; heat sink thermal resistance; mini water-cooled channels; power module integrated cooling design; thermal grease utilisation; Computational fluid dynamics; Coolants; Cooling; Electric resistance; Heat sinks; Multichip modules; Packaging machines; Temperature; Thermal resistance; Water heating;
Conference_Titel :
Industry Applications Conference, 2001. Thirty-Sixth IAS Annual Meeting. Conference Record of the 2001 IEEE
Conference_Location :
Chicago, IL, USA
Print_ISBN :
0-7803-7114-3
DOI :
10.1109/IAS.2001.955793