• DocumentCode
    1621808
  • Title

    The thin plate as a regularizer in Bayesian SPECT reconstruction

  • Author

    Lee, Soo-Jin ; Gindi, Gene

  • Author_Institution
    Korea Inst. of Sci. & Technol., Seoul, South Korea
  • Volume
    3
  • fYear
    1996
  • Firstpage
    1613
  • Abstract
    The attractions of the maximum-likelihood (ML) method for SPECT reconstruction, namely accurate system and noise modelling, are tempered by its unstable nature. The variety of Bayesian MAP approaches proposed in recent years can both stabilize the reconstructions and lead to better bias and variance. The authors´ own work (see IEEE Trans. on Medical Imaging, vol. MI-14, no. 4, p. 669-80, Dec. 1995) used a nonquadratic prior (the weak plate) that imposed piecewise smoothness on the first derivative of the solution to achieve results superior to those obtained using a nonquadratic prior (the weak membrane) that imposed piecewise smoothness of the zeroth derivative. By relaxing the requirement of imposing spatial discontinuities and using instead a quadratic (no discontinuities) smoothing prior, algorithms become easier to analyze, solutions easier to compute, and hyperparameter calculation becomes less of a problem. Here, the authors investigated whether the advantages of weak plate relative to weak membrane are retained when non-piecewise quadratic versions-the thin plate and membrane priors-are used. The authors used an EM-OSL (one-step-late) algorithm to compute MAP solutions with both these priors, and found that the thin plate exhibits better bias behaviour than the membrane at little cost in variance. Also, both priors outperform ML-EM in terms of bias and variance if practical stopping criteria are used for ML-EM. The net conclusion is that, while quadratic smoothing priors are not as good as piecewise versions, the simple modification of the membrane model to the thin late model leads to improved reconstructions in edge regions
  • Keywords
    Bayes methods; image reconstruction; medical image processing; single photon emission computed tomography; Bayesian SPECT reconstruction; accurate system modelling; bias behaviour; edge regions; improved reconstructions; maximum-likelihood method; medical diagnostic imaging; membrane priors; noise modelling; nonquadratic prior; nuclear medicine; spatial discontinuities; thin plate; thin plate regularizer; variance; Bayesian methods; Biomembranes; Context modeling; Image reconstruction; Iterative algorithms; Maximum likelihood estimation; Noise level; Noise measurement; Pollution measurement; Smoothing methods;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-3534-1
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1996.587933
  • Filename
    587933