Title :
About use of thermionic cathodes for the cold cathode magnetron ≪firing≫
Author_Institution :
Radioastron. Inst., Nat. Acad. of Sci. of Ukraine, Kharkiv, Ukraine
Abstract :
The magnetron designer advancing to the millimeter band short-wave region is faced with the problem of an increasing load to the electrodes, causes a catastrophically decreasing durability. This paper examines the use of secondary-emission cathodes (side cathodes) in order to extend the main cathode durability.
Keywords :
cold-cathode tubes; magnetrons; millimetre wave generation; secondary emission; thermionic cathodes; cold cathode magnetron firing; electrode durability; electrode load; main cathode durability; millimeter band short-wave region; secondary-emission cathodes; side cathodes; thermionic cathodes; Anodes; Cathodes; Cooling; Electrodes; Firing; Magnetic separation; Magnetic switching; Permeability; Temperature; Voltage;
Conference_Titel :
Physics and Engineering of Microwaves, Millimeter, and Submillimeter Waves, 2004. MSMW 04. The Fifth International Kharkov Symposium on
Print_ISBN :
0-7803-8411-3
DOI :
10.1109/MSMW.2004.1345974