DocumentCode :
1622629
Title :
About use of thermionic cathodes for the cold cathode magnetron ≪firing≫
Author :
Naumenko, V.D.
Author_Institution :
Radioastron. Inst., Nat. Acad. of Sci. of Ukraine, Kharkiv, Ukraine
Volume :
2
fYear :
2004
Firstpage :
492
Abstract :
The magnetron designer advancing to the millimeter band short-wave region is faced with the problem of an increasing load to the electrodes, causes a catastrophically decreasing durability. This paper examines the use of secondary-emission cathodes (side cathodes) in order to extend the main cathode durability.
Keywords :
cold-cathode tubes; magnetrons; millimetre wave generation; secondary emission; thermionic cathodes; cold cathode magnetron firing; electrode durability; electrode load; main cathode durability; millimeter band short-wave region; secondary-emission cathodes; side cathodes; thermionic cathodes; Anodes; Cathodes; Cooling; Electrodes; Firing; Magnetic separation; Magnetic switching; Permeability; Temperature; Voltage;