Title :
A priori motion models for four-dimensional reconstruction in gated cardiac SPECT
Author :
Lalush, David S. ; Cui, Lin ; Tsui, Benjamin M W
Author_Institution :
Dept. of Biomed. Eng., North Carolina Univ., Chapel Hill, NC, USA
Abstract :
The authors investigate the benefit of incorporating a priori assumptions about cardiac motion in a fully four-dimensional (4D) reconstruction algorithm for gated cardiac SPECT. Previous work has shown that non-motion-specific 4D Gibbs priors enforcing smoothing in time and space can control noise while preserving resolution. Here, the authors evaluate methods for incorporating known heart motion in the Gibbs prior model. The new model is derived by assigning motion vectors to each 4D voxel, defining the movement of that volume of activity into the neighboring time frames. Weights for the Gibbs cliques are computed based on these “most likely” motion vectors. To evaluate, the authors employ the mathematical cardiac-torso (MCAT) phantom with a new dynamic heart model that simulates the beating and twisting motion of the heart. Sixteen realistically-simulated gated datasets were generated, with noise simulated to emulate a real Tl-201 gated SPECT study. Reconstructions were performed using several different reconstruction algorithms, all modeling nonuniform attenuation and three-dimensional detector response. These include ML-EM with 4D filtering, 4D MAP-EM without prior motion assumption, and 4D MAP-EM with prior motion assumptions. The prior motion assumptions included both the correct motion model and incorrect models. Results show that reconstructions using the 4D prior model can smooth noise and preserve time-domain resolution more effectively than 4D linear filters. The authors conclude that modeling of motion in 4D reconstruction algorithms can be a powerful tool for smoothing noise and preserving temporal resolution in gated cardiac studies
Keywords :
biomechanics; cardiology; image resolution; medical image processing; motion estimation; physiological models; single photon emission computed tomography; 4D linear filters; Tl; Tl-201 gated SPECT; a priori motion models; cardiac motion; dynamic heart model; four-dimensional reconstruction; gated cardiac SPECT; mathematical cardiac-torso phantom; medical diagnostic imaging; nonuniform attenuation; nuclear medicine; reconstruction algorithms; resolution preservation; smoothing; three-dimensional detector response; time-domain resolution; Attenuation; Computational modeling; Detectors; Heart; Imaging phantoms; Mathematical model; Noise generators; Nonlinear filters; Reconstruction algorithms; Smoothing methods;
Conference_Titel :
Nuclear Science Symposium, 1996. Conference Record., 1996 IEEE
Conference_Location :
Anaheim, CA
Print_ISBN :
0-7803-3534-1
DOI :
10.1109/NSSMIC.1996.588010