DocumentCode :
1625520
Title :
Improvement of stability of electromagnetic flowmeter with non-wetted electrodes in low-conductivity liquid measurement
Author :
Nojiri, Hiroaki ; Kimura, Tatsuya
Author_Institution :
Toshiba Ind. & Power Syst. & Services Co., Tokyo, Japan
Volume :
2
fYear :
2004
Firstpage :
1554
Abstract :
An electromagnetic flowmeter is a flowmeter that has many features including high accuracy and no pressure losses. However, it is difficult for conventional electromagnetic flowmeters with wetted electrodes to measure the flow of liquids such as low-conductivity fluids, high-concentration slurry fluids and adhesive fluids. An electromagnetic flowmeter that uses non-wetted electrodes has been developed to deal with this problem. A larger variety of low-conductivity fluids can now be measured especially by improving the resistance to noise. It is accomplished to investigate the characteristics of flow noise.
Keywords :
electrodes; flow control; flowmeters; electromagnetic flowmeter stability; flow noise resistance; low-conductivity liquid measurement; nonwetted electrodes;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
SICE 2004 Annual Conference
Conference_Location :
Sapporo
Print_ISBN :
4-907764-22-7
Type :
conf
Filename :
1491674
Link To Document :
بازگشت