DocumentCode :
1625667
Title :
Timing recovery for sampling detectors in digital magnetic recording
Author :
Shafiee, Hamid
Author_Institution :
Texas Instrum. Inc., Dallas, TX, USA
Volume :
1
fYear :
1996
Firstpage :
577
Abstract :
The emerging synchronous detectors in digital recording systems require precise sampling of the readback waveform. In this paper, a general minimum-mean-square-error timing recovery approach is presented which could be applied to both partial response and decision feedback systems. We also investigate a related class of timing recovery algorithms which utilize the characteristics of the channel impulse response. A performance comparison of the two approaches on a set of experimental data, equalized to a class IV partial response target, is also presented
Keywords :
decision feedback equalisers; digital magnetic recording; least mean squares methods; partial response channels; receivers; signal sampling; synchronisation; transient response; channel impulse response; class IV partial response target; decision feedback systems; digital magnetic recording; digital recording systems; general minimum-mean-square-error timing recovery approach; partial response systems; performance comparison; readback waveform; sampling detectors; synchronous detectors; timing recovery; Decision feedback equalizers; Detectors; Digital magnetic recording; Digital recording; Finite impulse response filter; Frequency synchronization; Low pass filters; Phase detection; Sampling methods; Timing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Communications, 1996. ICC '96, Conference Record, Converging Technologies for Tomorrow's Applications. 1996 IEEE International Conference on
Conference_Location :
Dallas, TX
Print_ISBN :
0-7803-3250-4
Type :
conf
DOI :
10.1109/ICC.1996.542262
Filename :
542262
Link To Document :
بازگشت