• DocumentCode
    1628784
  • Title

    Influence of Variable Impedance Terminations and Input Voltages on the Operating Conditions of an Under-Matched Magnetically-Insulated Transmission Line

  • Author

    Bailey, Vernon L. ; Corcoran, Patrick ; Johnson, David L. ; Smith, Ian ; Oliver, Bryan ; Maenchen, John

  • Author_Institution
    L-3 Commun. Pulse Sci., San Leandro
  • fYear
    2007
  • Firstpage
    757
  • Lastpage
    757
  • Abstract
    Summary form only given. Termination of a magnetically-insulated transmission line (MITL) with an impedance that is less than the matched MITL operating impedance launches a re-trapping wave back up the MITL toward the source. A previous investigation obtained the relationship for the MITL operating conditions (voltage and current) after the passage of the re-trapping wave that depended on the input voltage, the termination impedance, and the MITL operating conditions based on parapotential flow at minimum current. The relationship was in agreement with detailed particle-in-cell (PIC) simulations and experiments of the re-trapping wave process for large area diodes. The scaling law and simulations however were only applied to a constant input (forward going) voltage and termination impedance. This work extends those PIC simulations and wave analyses to MITL operating conditions for termination impedances and input voltages that are functions of time. We first examine the case in which the input voltage is constant and the impedance changes in a staircase manner. These results are then extended to termination impedances that are continuously varying functions of time. The complementary case of fixed termination impedances and a variable input or forward going voltage will also be presented. The MITL operating conditions after the passage of the re-trapping will be examined as a function of the time history of the termination impedance and input voltage. Particle-in- cell simulations will be used extensively in the analyses and compared with linear and non-linear wave analyses. The objective of the work is to determine if the operating conditions of an under-matched magnetically insulated transmission line can be represented by a simple state function or do the final operating conditions depend on the previous time history of the termination impedance and input voltage.
  • Keywords
    impedance matching; transmission lines; MITL; PIC simulations; parapotential flow; particle-in-cell simulations; re-trapping wave; under-matched magnetically-insulated transmission line; variable impedance terminations; Analytical models; Diodes; Forward contracts; History; Impedance; Insulation; Laboratories; Magnetic analysis; Transmission lines; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
  • Conference_Location
    Albuquerque, NM
  • ISSN
    0730-9244
  • Print_ISBN
    978-1-4244-0915-0
  • Type

    conf

  • DOI
    10.1109/PPPS.2007.4346063
  • Filename
    4346063