• DocumentCode
    1630515
  • Title

    Saturation in synchronous machines due to voltage sags

  • Author

    Carlsson, Fredrik

  • Author_Institution
    Electr. Eng., R. Inst. of Technol., Stockholm, Sweden
  • Volume
    3
  • fYear
    2003
  • Firstpage
    1571
  • Abstract
    Voltage sags and voltage interruptions are huge power quality problems for many industries. Voltage sags cause, apart from eventual tripping, flux saturation, which cause large currents. This paper illustrates how the stator flux in a synchronous machine changes during voltage sags. It is shown that for some voltage sags, there will be flux saturation. Flux saturation causes both large currents and torque; these may quicken the aging of the machine. A comparison is done with a model without saturation included. This study includes only three-phase symmetrical voltage sags.
  • Keywords
    ageing; magnetic flux; power supply quality; stators; synchronous machines; aging; flux saturation; power quality; stator flux; synchronous machine; synchronous machines saturation; three-phase symmetrical voltage sags; tripping; voltage sags; Electrical equipment industry; Electrical products industry; Equations; Machinery production industries; Power quality; Shafts; Stators; Synchronous machines; Torque; Voltage fluctuations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
  • Print_ISBN
    0-7803-7817-2
  • Type

    conf

  • DOI
    10.1109/IEMDC.2003.1210660
  • Filename
    1210660