DocumentCode :
1630552
Title :
The active-bridge oscillator for use with liquid loaded QCM sensors
Author :
Wessendorf, Kuri O.
Author_Institution :
Sandia Nat. Labs., Albuquerque, NM, USA
fYear :
2001
fDate :
6/23/1905 12:00:00 AM
Firstpage :
400
Lastpage :
407
Abstract :
This unique bridge-type oscillator design permits liquid-loaded operation of QCM (quartz crystal microbalance) resonators with a simple, low parts count and inexpensive oscillator. This is achieved using "active-bridge" operation, which eliminates the need for the expensive and complex ALC (automatic level control) circuits typically used in high-performance oscillators designed for these applications. The Active-Bridge oscillator absorbs the wide dynamic range of resonator loss by varying the circuit operating Q as a function of the resonator loss. The output amplitude is relatively proportional to resonator loss. This design has demonstrated the ability to servo a loaded QCM resonator to within a few degrees of zero impedance-phase over a wide range of resonator loss, 300 Ω to approximately 3k Ω. This corresponds roughly to a liquid viscosity range of 1 to 120 cP, assuming a density close to one
Keywords :
crystal oscillators; electric sensing devices; microbalances; 300 Ω to 3 kΩ; 300 ohm to 3 kohm; QCM; active-bridge; bridge-type oscillator design; output amplitude; quartz crystal microbalance; resonator loss; Automatic logic units; Bridge circuits; Capacitance; Dynamic range; Impedance; Inductors; Level control; Oscillators; Shunt (electrical); Viscosity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Frequency Control Symposium and PDA Exhibition, 2001. Proceedings of the 2001 IEEE International
Conference_Location :
Seattle, WA
ISSN :
1075-6787
Print_ISBN :
0-7803-7028-7
Type :
conf
DOI :
10.1109/FREQ.2001.956260
Filename :
956260
Link To Document :
بازگشت