Summary form only given. Sterilization of living tissue and sensitive biomaterials require non-thermal plasma. Although there are many ways to generate non-thermal plasma at low pressure of different gases, for living tissue sterilization and blood coagulation uniform plasma in air at atmospheric pressure is crucial. On the other hand, when generating plasma at atmospheric pressure, such as by using RF power, a question arises about temperature. Most kinds of plasmas tend to have higher temperature than safe to use for sensitive treatment because of significant power deposition. Dielectric barrier discharge (DBD) is a very easy and cheap method for building systems and generating non-thermal atmospheric pressure plasma. This technique has been used for ozone production for more than one and a half century. Nevertheless, conventional atmospheric pressure DBDs in air may also have some difficulties to be used for medical treatment. When ignited in air at atmospheric pressure, they assume a filamentary structure because of streamers. These filaments are undesired for sensitive treatments due to having strong local heating effect. Thus DBD has to be more uniform. Latter can be done by applying pulsed power with pulse duration shorter than streamer formation time. To generate atmospheric pressure uniform plasma in air for living tissue sterilization and blood coagulation, we have developed a new nanosecond pulsed DBD system with only few tens of nanosecond pulse width, using point to plane configuration with customized circuit. Nanosecond pulsed DBD was characterized by electrical and spectroscopic analyses. Voltage pulse width was obtained approximately 20 ns at the half height and with 3 kV/ns front. Uniformity of the nanosecond pulsed DBD has been measured qualitatively by using photofilm where Lichtenberg figures of single pulses do not show any trace of filament. Additionally it was observed that discharge ignites uniformly over large range of gap distances (0.1-4 m- m). Further details on characterization and results about new uniform DBD will be presented.
Keywords :
bioelectric phenomena; biological tissues; blood; discharges (electric); patient treatment; plasma applications; plasma pressure; plasma production; Lichtenberg figures; RF power; blood coagulation; electrical analysis; filamentary structure; heating effect; living tissue sterilization; medical treatment; nanosecond pulsed uniform dielectric barrier discharge; nonthermal atmospheric pressure plasma generation; ozone production; photofilm; spectroscopic analysis; Atmospheric-pressure plasmas; Blood; Coagulation; Dielectrics; Gases; Plasma temperature; Pulse circuits; Pulse measurements; Space vector pulse width modulation; Temperature sensors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Science, 2007. ICOPS 2007. IEEE 34th International Conference on
Conference_Location :
Albuquerque, NM
ISSN :
0730-9244
Print_ISBN :
978-1-4244-0915-0
Type :
conf
DOI :
10.1109/PPPS.2007.4346136
Filename :
4346136
Link To Document :
بازگشت