• DocumentCode
    1630909
  • Title

    Guided SH-SAW sensors for liquid-phase detection

  • Author

    Josse, Fabien ; Bender, Florian ; Cernosek, Richard W. ; Zinszer, Kristofer

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Marquette Univ., Milwaukee, WI, USA
  • fYear
    2001
  • fDate
    6/23/1905 12:00:00 AM
  • Firstpage
    454
  • Lastpage
    461
  • Abstract
    The design and performance of guided shear horizontal surface acoustic wave (guided SH-SAW) devices on LiTaO3 substrates are investigated for high sensitivity biochemical sensor in liquids. The device sensitivity to mass and viscoelastic loading is increased using a thin guiding layer of (cross-linked or cured) poly(methyl methacrylate) (PMMA) or cyanoethylcellulose (CEC) on the device surface. The devices have been tested in biosensing and chemical sensing experiments. Suitable design principles for these applications are discussed with regard to wave guidance, electrical passivation of the interdigital transducers (IDT) from the liquid environments, acoustic loss and sensor signal distortion. In biosensing experiments, using optimal PMMA thickness of approximately 2 μm, mass sensitivity greater than 1500 Hz/(ng/mm2) is demonstrated, resulting in a minimum detection limit less than 20 pg/mm2. For chemical sensor experiments, it is found that optimal waveguide thickness must be modified to account for the chemically sensitive layer
  • Keywords
    biosensors; chemical sensors; interdigital transducers; losses; passivation; polymer films; sensitivity; surface acoustic wave sensors; 2 micron; IDT; LiTaO3; LiTaO3 substrates; PMMA thin guiding layer; acoustic loss; biosensing experiments; chemical sensing experiments; chemically sensitive layer; cyanoethylcellulose thin guiding layer; electrical passivation; guided SH-SAW devices; guided shear horizontal SAW sensors; high sensitivity biochemical sensor; interdigital transducers; liquid environments; liquid-phase detection; mass loading; optimal PMMA thickness; poly(methyl methacrylate; sensor signal distortion; viscoelastic loading; Acoustic sensors; Acoustic signal detection; Acoustic testing; Acoustic waves; Biosensors; Chemical sensors; Elasticity; Liquids; Surface acoustic wave devices; Viscosity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Frequency Control Symposium and PDA Exhibition, 2001. Proceedings of the 2001 IEEE International
  • Conference_Location
    Seattle, WA
  • ISSN
    1075-6787
  • Print_ISBN
    0-7803-7028-7
  • Type

    conf

  • DOI
    10.1109/FREQ.2001.956273
  • Filename
    956273