DocumentCode
1631718
Title
Experimental evaluation of mitigation techniques for bearing currents in inverter-supplied drive-systems - investigations on induction motors up to 500 kW
Author
Muetze, A. ; Binder, A.
Author_Institution
Dept. of Electr. Energy Conversion, Darmstadt Univ. of Technol., Germany
Volume
3
fYear
2003
Firstpage
1859
Abstract
A research program for systematic investigation of the influence of different system parameters on additional bearing currents at inverter-operation has been set up. This paper discusses the influence of the cable type and of different mitigation techniques such as filters and insulated as well as hybrid bearings on the bearing current phenomena for power levels 11 kW to 500 kW. The impact of these parameters depends significantly on the type of bearing current occurring and hence on the motor size.
Keywords
DC-AC power convertors; induction motor drives; invertors; machine bearings; machine testing; 11 to 500 kW; bearing currents; hybrid bearings; inverter-operation; invertor-supplied induction motor drives; mitigation techniques; system parameters; Cable insulation; Filters; Induction motors; Insulated gate bipolar transistors; Inverters; Rotors; Stators; Testing; Variable speed drives; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
Print_ISBN
0-7803-7817-2
Type
conf
DOI
10.1109/IEMDC.2003.1210706
Filename
1210706
Link To Document