• DocumentCode
    1632567
  • Title

    Intra-luminal injection of ferro-fluid for magnetic bowel retraction in minimal access surgery

  • Author

    Wang, Zhigang ; Brown, Andrew W. ; Brown, Stuart I. ; Wang, Lijun ; Andre, Pascal ; Florence, Gordon J. ; Cuschieri, Alfred

  • Author_Institution
    Inst. for Med. Sci. & Technol. (IMSaT), Univ. of Dundee, Dundee, UK
  • fYear
    2010
  • Firstpage
    168
  • Lastpage
    173
  • Abstract
    Safe and effective manipulation of soft tissue during laparoscopic and other minimal access surgical (MAS) procedures can be enabled by use of electromagnetic force. We investigated magnet interaction force using finite element modeling (FEM) and tensiometer measurement, and found that our FEM results were in good agreement with measurement data. Then, we describe a novel method of ferro-magnetisation of a bowel segment for magnetic retraction. Simulated surgical procedures were carried out using an ex-vivo pig bowel model. Ferromagnetic microparticles were dispersed in a viscous carrier liquid, and injected intra-luminally to the inner (mucosal) aspect of the bowel wall. The injected magnetic microparticles were then retracted towards a magnetic probe which was located external to the bowel wall, and magnetic interaction force between the injected magnetic aggregation and the probe was found sufficient to manipulate the bowel segment. In this preliminary experiment, the probe was consisted of small Neodymium magnet discs, and magnetic attraction force can be changed by adding or reducing the number of magnet discs used. Magnetic fluids with different concentration were prepared and injected without difficulty. To solidify the magnetic aggregation, a medical grade cyanoacrylate liquid was injected sequentially and mixed in-situ with the injected microparticles aggregation underneath the magnet probe. The ferromagnetic coagulum appears to be a promising method for safe and effective magnetic bowel retraction in MAS.
  • Keywords
    biomagnetism; ferromagnetic materials; finite element analysis; magnetic fluids; magnetisation; surgery; FEM; bowel segment; cyanoacrylate liquid; electromagnetic force; ex-vivo pig bowel model; ferro-fluid; ferro-magnetisation; ferromagnetic coagulum; ferromagnetic microparticles; finite element modeling; injected magnetic microparticles; intra-luminal injection; laparoscopic surgery; magnet interaction force; magnetic aggregation; magnetic attraction force; magnetic bowel retraction; magnetic fluids; magnetic probe; magnetic retraction; minimal access surgery; minimal access surgical procedures; neodymium magnet discs; simulated surgical procedures; soft tissue manipulation; tensiometer measurement; Biological system modeling; Fluids; Lead; Media; Predictive models; Thickness measurement; Finite Element Method (FEM); Force; Magnetic particles; Minimal Access Surgery (MAS); Tissue Retraction;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronics and Embedded Systems and Applications (MESA), 2010 IEEE/ASME International Conference on
  • Conference_Location
    Qingdao
  • Print_ISBN
    978-1-4244-7101-0
  • Type

    conf

  • DOI
    10.1109/MESA.2010.5552080
  • Filename
    5552080