  • Abstract
    The design of compact, high voltage switches is generally plagued by the tradeoff between reduced size and the probabilities of bulk and surface breakdown. Moreover, typical breakdown field values for wide classes of materials with desirable electrical and mechanical properties are unavailable. In the development of a compact gas switch, capable of holding off voltages of up to 1 MV at repetition rates of 200 Hz, a criterion to insure the inhibition of surface flashover in a high pressure atmosphere has been developed. The switch is composed of copper tungsten electrodes with a coaxial Torlon pressure containment housing of length 12.7 cm and a diameter of 15.3 cm. Pulse repetition rates in the 100´s of Hz are achieved by using moderate hydrogen pressures as the insulating medium. The electrodes are shaped to produce a uniform field distribution in the gap with an adjustable spacing of 0.5, 0.75 and 1.0 cm. Additional stress is put on the switch by charging with a dual-resonant pulse transformer.
  • Keywords
    electric fields; electrodes; mechanical properties; pulse transformers; pulsed power switches; surface discharges; 0.5 to 1 cm; 1 MV; 12.7 cm; 15.3 cm; 200 Hz; adjustable spacing; breakdown field values; bulk breakdown; coaxial Torlon pressure containment housing; compact self break switch; copper tungsten electrodes; dual-resonant pulse transformer; electrical properties; high pressure atmosphere; high repetition rate operation; high voltage switches; mechanical properties; pulse repetition rates; surface breakdown; surface flashover inhibition; uniform field distribution; Atmosphere; Breakdown voltage; Coaxial components; Copper; Electric breakdown; Electrodes; Flashover; Mechanical factors; Switches; Tungsten;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 1999. Digest of Technical Papers. 12th IEEE International
  • Conference_Location
    Monterey, CA, USA
  • Print_ISBN
    0-7803-5498-2
  • Type

    conf

  • DOI
    10.1109/PPC.1999.823737
  • Filename
    823737