Abstract
Results of anisotropic magneto-resistive (AMR) sensor dose rate and total dose behavior are presented. Experiments conducted at LINAC and pulsed electron accelerator. A good agreement of theoretical and experimental transfer functions was found. Investigated AMR-sensor radiation behavior can affect device operation in space applications.
Keywords
electron accelerators; enhanced magnetoresistance; linear accelerators; sensors; transfer functions; AMR sensor dose rate; AMR-sensor radiation behavior; LINAC; TID effects; anisotropic magnetoresistive sensor; pulsed electron accelerator; total dose behavior; transfer functions; Bridge circuits; Magnetic field measurement; Magnetic fields; Radiation effects; Resistance; Sensitivity; Transfer functions;