• DocumentCode
    163709
  • Title

    Investigation of dose rate and TID effects in anisotropic magneto resistive sensor

  • Author

    Grebenkina, A.V. ; Boychenko, Dmitry V. ; Nikiforov, Alexander Y. ; Telets, Vitaliy A. ; Amelichev, V.V. ; Kharitonov, V.A.

  • Author_Institution
    Nat. Res. Nucl. Univ. “MEPHI”, Moscow, Russia
  • fYear
    2014
  • fDate
    12-14 May 2014
  • Firstpage
    133
  • Lastpage
    135
  • Abstract
    Results of anisotropic magneto-resistive (AMR) sensor dose rate and total dose behavior are presented. Experiments conducted at LINAC and pulsed electron accelerator. A good agreement of theoretical and experimental transfer functions was found. Investigated AMR-sensor radiation behavior can affect device operation in space applications.
  • Keywords
    electron accelerators; enhanced magnetoresistance; linear accelerators; sensors; transfer functions; AMR sensor dose rate; AMR-sensor radiation behavior; LINAC; TID effects; anisotropic magnetoresistive sensor; pulsed electron accelerator; total dose behavior; transfer functions; Bridge circuits; Magnetic field measurement; Magnetic fields; Radiation effects; Resistance; Sensitivity; Transfer functions;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microelectronics Proceedings - MIEL 2014, 2014 29th International Conference on
  • Conference_Location
    Belgrade
  • Print_ISBN
    978-1-4799-5295-3
  • Type

    conf

  • DOI
    10.1109/MIEL.2014.6842103
  • Filename
    6842103