DocumentCode
1638414
Title
Compensation of the effects of the forward voltage drop of power switches on direct torque controlled synchronous machine drive
Author
Tang, Lixin ; Rahman, Muhammed Faz
Author_Institution
Sch. of Electr. Eng. & Telecommun., New South Wales Univ., Sydney, NSW, Australia
Volume
1
fYear
2003
Firstpage
389
Abstract
The direct torque control scheme is an outstanding scheme based on space vector theory. However, at low speed, the performance is not so desirable. The effect of forward voltage drop and dead-time are analyzed and compensated in this paper. Modeling results show that the blindness to the forward voltage drop of the power switches may cause oscillation in the flux and torque of the machine. A simple compensation scheme is proposed and used in experiment to solve the problem. Better low speed performance has been observed with the compensated DTC IPMSM drive system.
Keywords
machine control; magnetic flux; oscillations; switches; synchronous motor drives; torque control; dead-time effect compensation; direct torque control; flux oscillation; forward voltage drop effects compensation; power switches; space vector theory; synchronous machine drive; torque oscillation; Couplings; Hysteresis; Inverters; Sampling methods; Stators; Synchronous machines; System performance; Telecommunication control; Torque control; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Electric Machines and Drives Conference, 2003. IEMDC'03. IEEE International
Print_ISBN
0-7803-7817-2
Type
conf
DOI
10.1109/IEMDC.2003.1211293
Filename
1211293
Link To Document