DocumentCode :
16386
Title :
Objective Study of Sensor Relevance for Automatic Cough Detection
Author :
Drugman, Thomas ; Urbain, Jerome ; Bauwens, N. ; Chessini, R. ; Valderrama, Carlos ; Lebecque, P. ; Dutoit, Thierry
Author_Institution :
Univ. of Mons, Mons, Belgium
Volume :
17
Issue :
3
fYear :
2013
fDate :
May-13
Firstpage :
699
Lastpage :
707
Abstract :
The development of a system for the automatic, objective, and reliable detection of cough events is a need underlined by the medical literature for years. The benefit of such a tool is clear as it would allow the assessment of pathology severity in chronic cough diseases. Even though some approaches have recently reported solutions achieving this task with a relative success, there is still no standardization about the method to adopt or the sensors to use. The goal of this paper is to study objectively the performance of several sensors for cough detection: ECG, thermistor, chest belt, accelerometer, contact, and audio microphones. Experiments are carried out on a database of 32 healthy subjects producing, in a confined room and in three situations, voluntary cough at various volumes as well as other event categories which can possibly lead to some detection errors: background noise, forced expiration, throat clearing, speech, and laugh. The relevance of each sensor is evaluated at three stages: mutual information conveyed by the features, ability to discriminate at the frame level cough from these latter other sources of ambiguity, and ability to detect cough events. In this latter experiment, with both an averaged sensitivity and specificity of about 94.5%, the proposed approach is shown to clearly outperform the commercial Karmelsonix system which achieved a specificity of 95.3% and a sensitivity of 64.9%.
Keywords :
accelerometers; bioelectric potentials; diseases; electrocardiography; medical signal detection; medical signal processing; microphones; noise; sensors; speech; speech processing; thermistors; ECG; Karmelsonix system; accelerometer; audio microphone; automatic cough detection; background noise; chest belt; chronic cough disease; electrocardiography; forced expiration; laugh; pathology severity assessment; sensor; speech; thermistor; throat clearing; Accelerometers; Belts; Electrocardiography; Feature extraction; Microphones; Monitoring; Mutual information; Audio processing; biomedical engineering; cough detection; cystic fibrosis; multimodal; neural network; sensor;
fLanguage :
English
Journal_Title :
Biomedical and Health Informatics, IEEE Journal of
Publisher :
ieee
ISSN :
2168-2194
Type :
jour
DOI :
10.1109/JBHI.2013.2239303
Filename :
6415229
Link To Document :
بازگشت