    Forward electrocardiography based on measured data

  • Author

    Huiskamp, Geertjan ; Van Oosterom, Adriaan

  • Author_Institution
    Lab. of Med. Phys. & Biophys., Nijmegen Univ., Netherlands
  • fYear
    1989
  • Firstpage
    189
  • Abstract
    A simulation study on the ECG is performed using the measured thorax geometry of a healthy subject and a measured ventricular activation sequence, known from the literature. Resulting QRS waveforms are compared with those actually measured on the subject. An adapted activation sequence is derived which, while differing only a small amount from the measured data, produces ECGs more closely resembling the ones measured on the subject. Measurements of the QRS complexes of the healthy subject have been performed using a 64-channel body-surface mapping system
  • Keywords
    electrocardiography; 64-channel body-surface mapping system; QRS waveforms; forward ECG; healthy subject; measured data; thorax geometry; ventricular activation sequence; Electrocardiography; Heart; Inverse problems; Lungs; Magnetic resonance imaging; Medical simulation; Performance evaluation; Shape measurement; Time measurement; Torso;