DocumentCode :
1641290
Title :
The measurement uncertainty of electromagnetic conducted immunity test using CDN
Author :
Mun, Jun-Chul ; Lim, Young-Chae ; Kim, Yung-Kyu
Author_Institution :
Minist. of Inf. & Commun. of Radio Res. Lab
Volume :
1
fYear :
2005
Firstpage :
650
Abstract :
We estimated the measurement uncertainty of electromagnetic conducted immunity using CDN (coupling/decoupling network). We analyzed the contribution factors for the uncertainty and obtained the uncertainty by each factor. The contributions of the uncertainty are the repeatability of measurement system; harmonics of power amplifier; the accuracy of power meter; mismatch between power amplifier and CDN; and mismatch between power meter and QDN. We obtained that the expanded uncertainty is 1.17 dB in level of confidence and plusmn 0.43 V of error range in 3 V. These results could tell that the most important uncertainty contribution is mismatched between measurement system in electromagnetic conducted immunity test. Therefore, we know that it is important to match impedance on electromagnetic conducted immunity test
Keywords :
electromagnetic compatibility; immunity testing; measurement uncertainty; coupling-decoupling network; electromagnetic conducted immunity test; measurement uncertainty; Cables; Electromagnetic coupling; Electromagnetic radiation; Frequency; Impedance; Measurement uncertainty; Medical services; Power amplifiers; Radiofrequency amplifiers; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave, Antenna, Propagation and EMC Technologies for Wireless Communications, 2005. MAPE 2005. IEEE International Symposium on
Conference_Location :
Beijing
Print_ISBN :
0-7803-9128-4
Type :
conf
DOI :
10.1109/MAPE.2005.1617994
Filename :
1617994
Link To Document :
بازگشت