DocumentCode
1642306
Title
Hinged heat pipes for cooling notebook PCs
Author
Mochizuki, Masataka ; Saito, Yuji ; Goto, Kazuhiko ; Nguyen, Thang ; Ho, Phong ; Malcolm, Monica ; Morando, Michael P.
Author_Institution
Energy Syst. Lab., Fujikura Ltd., Tokyo, Japan
fYear
1997
Firstpage
64
Lastpage
72
Abstract
In an endeavor to provide a total passive cooling solution for high heat dissipating CPU in a notebook computer environment, a new cooling method called hinged heat pipes system has been developed and is introduced here. This system takes the heat away from the CPU and dissipates it to the back of the display screen (LCD) via means of heat pipes and hinged connector. Its concept and design is discussed. From testing results, we will be able to show that hinged heat pipes system is capable of dissipating 10-12 watts of heat generated from the CPU while maintaining its surface temperature at less than 95°C and not exceeding the thermal specification of LCD. We will also address the issue of thermal performance with respect to interfacing methods between heat pipes and hinged connector. Finally, we illustrate that hinged heat pipes cooling system is highly reliable through heat pipes´ reliability data
Keywords
cooling; fault tolerant computing; heat pipes; notebook computers; packaging; reliability; 10 to 12 W; high heat dissipating CPU; hinged heat pipes; notebook PCs; reliability data; surface temperature; total passive cooling solution; Contact resistance; Cooling; Heat sinks; Heat transfer; Personal communication networks; Space heating; Surface resistance; Temperature; Thermal conductivity; Thermal resistance;
fLanguage
English
Publisher
ieee
Conference_Titel
Semiconductor Thermal Measurement and Management Symposium, 1997. SEMI-THERM XIII., Thirteenth Annual IEEE
Conference_Location
Austin, TX
ISSN
1065-2221
Print_ISBN
0-7803-3793-X
Type
conf
DOI
10.1109/STHERM.1997.566784