Abstract :
We implemented a microfluidic signal generator chip for the in-vitro study of the nervous system of Aplysia californica under localized chemical stimulation. The PDMS chip implements a one-bit pulse-code modulator that digitally controls the concentration of the non-hydrolysable cholinergic agonist carbachol injected directly above a ganglion. The chip was successful in inducing a burst of ingestive patterns.
Keywords :
bioMEMS; biochemistry; biomedical electronics; digital control; lab-on-a-chip; medical control systems; microfluidics; neurophysiology; pulse code modulation; signal generators; Aplysia californica ganglion; PDMS chip; carbachol injection; digital control; in-vitro study; ingestive patterns; localized chemical stimulation; microfluidic signal generator chip; nervous system; nonhydrolysable cholinergic agonist; one-bit pulse-code modulator; Chemicals; Frequency; Microfluidics; Nervous system; Phase change materials; Plugs; Pulse modulation; Signal generators; Solvents; Valves;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Circuits and Systems Conference, 2008. BioCAS 2008. IEEE
Conference_Location :
Baltimore, MD
Print_ISBN :
978-1-4244-2878-6
Electronic_ISBN :
978-1-4244-2879-3
Type :
conf
DOI :
10.1109/BIOCAS.2008.4696935
Filename :
4696935
Link To Document :
بازگشت