• DocumentCode
    1646665
  • Title

    Partial discharge location on power cables using linear prediction

  • Author

    Bidhendi, Hossein Nabi ; Su, Qi

  • Author_Institution
    Centre for Electr. Power Eng., Monash Univ., Clayton, Vic., Australia
  • Volume
    1
  • fYear
    1997
  • Firstpage
    406
  • Abstract
    In this paper a linear prediction technique is developed to separate a partial discharge signal from its echoes in a noisy environment. Based on the correlation which exists between the measuring values of a signal, it is possible to trace the signal. The signal can then be extracted from its echoes or background noise. Since the parameters of the prediction technique are determined by the recorded signal, very good results can be obtained from a noisy composite signal. This procedure can provide a good method to filter a composite signal when conventional methods fail
  • Keywords
    insulation testing; partial discharges; power cable insulation; power cable testing; prediction theory; background noise; composite signal filtering; echo; linear prediction; partial discharge location; power cable; signal extraction; Equations; Low pass filters; Noise level; Partial discharges; Position measurement; Power cables; Predictive models; Signal resolution; Stability; Working environment noise;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
  • Conference_Location
    Seoul
  • Print_ISBN
    0-7803-2651-2
  • Type

    conf

  • DOI
    10.1109/ICPADM.1997.617622
  • Filename
    617622