DocumentCode
1646784
Title
DC short-circuit treeing phenomenon and space charge effect in EPR at cryogenic temperature
Author
Minoda, Atsushi ; Nagao, Masayuki ; Kosaki, Masamitsu
Author_Institution
Dept. of Electr. & Electron. Eng., Toyohashi Univ. of Technol., Japan
Volume
1
fYear
1997
Firstpage
426
Abstract
Short-circuit tree initiation voltage of EPR at cryogenic temperature is much higher than that at room temperature. Space charge measurement was carried out using pulsed electroacoustic method. Injection of negative space charge occurred at room temperature from the cathode, but at cryogenic temperature the injection is very limited. For DC electrical insulation, space charge is less problematic at cryogenic temperature than at room temperature
Keywords
cryogenics; ethylene-propylene rubber; space charge; trees (electrical); DC short-circuit treeing; EPR; cryogenic temperature; electrical insulation; pulsed electroacoustic method; space charge; Charge measurement; Cryogenics; Current measurement; Paramagnetic resonance; Pulse measurements; Pulsed electroacoustic methods; Space charge; Temperature measurement; Trees - insulation; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
Conference_Location
Seoul
Print_ISBN
0-7803-2651-2
Type
conf
DOI
10.1109/ICPADM.1997.617627
Filename
617627
Link To Document