DocumentCode :
1647349
Title :
Phenomena and mechanism of electrical tree in DGEBA/MDA/GN system
Author :
An, Hyun-Soo ; Song, Young-Wook ; Shim, Mi-Ja ; Kim, Sang-Wook
Author_Institution :
Dept. of Chem. Eng., Seoul City Univ., South Korea
Volume :
1
fYear :
1997
Firstpage :
451
Abstract :
Electrical tree, one of the main cause of breakdown in insulating materials, was affected by temperature, applied voltage, frequency, etc. In this study, the toughness of epoxy resin system was improved as GN was introduced to DGEBA/MDA system and the phenomena and mechanism of electrical tree in DGEBA/MDA/GN system under various voltages and temperatures were investigated. As voltages were applied to epoxy resin system, the growth rate of electrical tree showed the sigmoid shape. The growth rate of electrical tree increased with the increment of applied voltages. As temperature increased, the growth rate of electrical tree increased and the phenomena of tree mere more complex
Keywords :
epoxy insulation; trees (electrical); DGEBA/MDA/GN system; breakdown; electrical tree; epoxy resin; insulating material; Breakdown voltage; Cities and towns; Conducting materials; Dielectrics and electrical insulation; Epoxy resins; Frequency; Needles; Power transformer insulation; Temperature; Trees - insulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Properties and Applications of Dielectric Materials, 1997., Proceedings of the 5th International Conference on
Conference_Location :
Seoul
Print_ISBN :
0-7803-2651-2
Type :
conf
DOI :
10.1109/ICPADM.1997.617633
Filename :
617633