DocumentCode :
1649509
Title :
Influence of sample insertion hole on resonant cavity perturbation measuring method
Author :
Ikeda, M. ; Fukunaga, T. ; Miura, T.
Author_Institution :
TDK Corp., Chiba, Japan
Volume :
2
fYear :
2003
Firstpage :
1423
Abstract :
Influence of sample insertion holes in resonant cavity for a measuring fixture was investigated experimentally and numerically. Shift of the resonant frequency caused by loaded sample decreased when the cavity height decreased or dielectric constant of a sample increased. Employing tall cavity improved measurement error. Using commercial simulators, it was found that disturbance of electric field near the sample insertion hole caused deviation of resonant frequency from the ideally closed cavity. The simulation result was inspected from the viewpoint of physical rationality.
Keywords :
cavity resonators; measurement errors; microwave measurement; permittivity measurement; dielectric constant; electric field simulation; measurement error; resonant cavity perturbation measuring method; resonant frequency; sample insertion hole; Cavity perturbation methods; Dielectric constant; Dielectric measurements; Equations; Fixtures; Iris; Magnetic resonance; Microwave antenna arrays; Permittivity; Resonant frequency;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Symposium Digest, 2003 IEEE MTT-S International
Conference_Location :
Philadelphia, PA, USA
ISSN :
0149-645X
Print_ISBN :
0-7803-7695-1
Type :
conf
DOI :
10.1109/MWSYM.2003.1212639
Filename :
1212639