DocumentCode
1649528
Title
Active filter using cascade connection of switching regulators
Author
Ninomiya, Kei ; Harada, Koosuke ; Miyazaki, Izumo
Author_Institution
Dept. of Electron., Kyushu Univ., Fukuoka, Japan
fYear
1995
Firstpage
678
Lastpage
683
Abstract
The stability of cascade connected switched mode power converters is investigated. The first stage is the boost power converter for correcting power factor and the second stage is the buck power converter for regulating output voltage. In this paper, the authors show that increasing the feedforward gain of the first stage makes the second stage more stable and that good regulation is achieved by increasing the feedback gain of the second stage
Keywords
DC-DC power convertors; PWM power convertors; active filters; circuit stability; circuit testing; feedback; feedforward; power factor correction; power filters; power system harmonics; state-space methods; switched mode power supplies; switching circuits; voltage control; voltage regulators; active power filter; boost power converter; buck power converter; cascade connection; feedback gain; feedforward gain; output voltage regulation; power factor correction; stability; switched mode power converters; switching regulators; Active filters; Buck converters; Capacitors; Circuits; Feeds; Frequency; Reactive power; Regulators; Switching converters; Voltage control;