Abstract :
This paper presents the effect of the grading insulation in open and enclose type COS. Because the conventional open-type COS has the problem which isn´t strong for the wind with salt, we attempted to mitigate the electric field intensity at the inner and outer part of insulator in enclosed-type COS. The good mitigative effect of that is produced by the application of the grading insulation of the dielectric material
Keywords :
electric fields; electric fuses; explosions; insulators; switchgear; switchgear insulation; 22.9 kV; dielectric material; electric field distribution; enclosed-type COS; explosion fuse; grading insulation; insulator; open-type COS; salt; wind; Connectors; Contacts; Dielectric materials; Dielectrics and electrical insulation; Explosions; Fuses; Power transformer insulation; Protection; Short circuit currents; Wire;