  • Abstract
    A new method (ultrasonic computed velocimetry) to measure complete vector components of flow velocity is proposed. Using this method, it is possible to measure the flow velocity components both along and transverse to the beam axis. This method is able to simultaneously measure the signs and magnitude of the flow velocity components. Reflected ultrasound waves are used together with fully linear signal processing procedures. The first step is Fourier transformation but in the polar axis direction. Detailed procedures, numerical simulation and some experimental results are presented
  • Keywords
    Fourier transforms; flow measurement; ultrasonic measurement; Fourier transformation; flow velocity components; linear signal processing; reflected US waves; ultrasonic computed velocimetry; ultrasonic flow vector measurement; Array signal processing; Fluid flow measurement; Frequency; Numerical simulation; Propagation delay; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers; Ultrasonic variables measurement; Velocity measurement;