DocumentCode :
1658232
Title :
The Method of Pre-Warning for Safe Supply
Author :
Yi, Xuenong ; Zhang, Ying ; Gao, Yuqiong
Author_Institution :
Coll. of Urban Constr. & Environ. Eng., Univ. of Shanghai for Sci. & Technol., Shanghai
fYear :
2008
Firstpage :
4726
Lastpage :
4729
Abstract :
This paper provide a new methodology for finding the optimal layout of an early warning detection system (EWDS).Using the results of simulation of hydraulic and water quality in net work of pipes and taking t-hour level of service as the criteria, in the basis of dynamic matrix, a genetic algorithm (GA) and mathematical optimization are used to quantitatively evaluate the effectiveness of the EWDS. The methodology is demonstrated through EPANET Example 3. The results showed that this method provides efficient coverage of water distribution system.
Keywords :
alarm systems; contamination; genetic algorithms; safety; water supply; dynamic matrix; early warning detection system; genetic algorithm; hydraulic quality; mathematical optimization; pipes; prewarning method; safe supply; water distribution system; water quality; Biological system modeling; Contamination; Databases; Educational institutions; Genetic algorithms; Genetic engineering; Hazards; Monitoring; Security; Water pollution;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering, 2008. ICBBE 2008. The 2nd International Conference on
Conference_Location :
Shanghai
Print_ISBN :
978-1-4244-1747-6
Electronic_ISBN :
978-1-4244-1748-3
Type :
conf
DOI :
10.1109/ICBBE.2008.339
Filename :
4535219
Link To Document :
بازگشت