• DocumentCode
    1658490
  • Title

    Design of an improved acoustic plate mode delay line for biosensor applications

  • Author

    Andle, J.C. ; Josse, F. ; Vetelino, J.F. ; McAllister, D.J.

  • Author_Institution
    Dept. of Electr. Eng., Maine Univ., Orono, ME, USA
  • fYear
    1992
  • Firstpage
    287
  • Abstract
    The design of an improved acoustic plate mode (APM) biochemical sensing device is reported. The device, fabricated on a 0.5-mm-thick ZX-lithium niobate substrate, consists of a dual delay line configuration which could be used in either a vector voltmeter phase discriminator or a dual oscillator measurement system. The device exhibits excellent adjacent mode rejection without sacrificing the high sensitivity to electrical loadings. The device, which shows a better phase linearity, is currently being evaluated in various measurement systems as a chemical sensor or biosensor
  • Keywords
    biosensors; chemical sensors; surface acoustic wave devices; ultrasonic delay lines; LiNbO3 substrate; acoustic plate mode delay line; biochemical sensing device; biosensor; design; dual delay line configuration; dual oscillator measurement system; vector voltmeter phase discriminator; Acoustic devices; Acoustic measurements; Biosensors; Current measurement; Delay lines; Linearity; Niobium compounds; Oscillators; Phase measurement; Voltmeters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 1992. Proceedings., IEEE 1992
  • Conference_Location
    Tucson, AZ
  • Print_ISBN
    0-7803-0562-0
  • Type

    conf

  • DOI
    10.1109/ULTSYM.1992.275994
  • Filename
    275994