DocumentCode :
165892
Title :
An interactive GUI tool for thyroid Uptake studies using Gamma Camera
Author :
Vignesh, T. Sai ; Subramaniyan, V. Siva ; Rajamani, Kumar T. ; Siva Sankara Sai, S.
Author_Institution :
Dept. of Phys., Sri Sathya Sai Inst. of Higher Learning, Prasanthi Nilayam, India
fYear :
2014
fDate :
24-27 Sept. 2014
Firstpage :
305
Lastpage :
309
Abstract :
Thyroid uptake study is a technique that requires injection of a radio-isotope/radiotracer emitting gamma rays into the blood stream of the patient. Thyroid imaging is done by means of Thyroid Uptake imaging system. In the absence of a sophisticated system, imaging can also be done using Gamma Camera. By intravenously injecting 2 millicuries of Technetium-99m pertechnetate radio-isotope, serial thyroid images are acquired. This Uptake study provides Functional information and is useful for diagnosis and treatment of Hyperthyroidism. Thyroid uptake study done using Gamma Camera has to be calibrated at each laboratory using this technique. In our hospital it has been standardized that a tracer uptake of greater than 2% is considered Hyperthyroidism, between 0.5 and 2% is considered normal and less than 0.5% is considered Hypothyroidism. Thyroid Uptake is calculated based on the counts. Counts are nothing but the sum of all intensities in the selected region of the image. Gamma Camera uses a LEAP (Low Energy All Purpose) collimator which handles only photons emitted from radioi-sotopes having lower emission energies. So Technetium-99m is used which has its energy of emission around 140 keV. For a typical Thyroid Uptake Probe where Iodine-131 having greater emission energy of 364 keV is preferred, existing Thyroid Uptake software cannot be used. Therefore an Interactive GUI (Graphical User Interface) tool was developed for thyroid Uptake studies using Fiji for determination of tracer uptake by manually drawing the ROI (Region of Interest) around left and right thyroid lobes separately. Developed tool was tested on 30 real time thyroid cases (26 female and 4 male) and the uptake values obtained are compared with those obtained from the existing software tool.
Keywords :
bioinformatics; blood; diseases; gamma-rays; graphical user interfaces; medical computing; patient diagnosis; patient treatment; LEAP; ROI; functional information; gamma camera; graphical user interface; hyperthyroidism diagnosis; hyperthyroidism treatment; interactive GUI tool; low energy all purpose collimator; patient blood stream; region of interest; thyroid uptake; tracer uptake determination; Biomedical imaging; Cameras; Graphical user interfaces; Nuclear medicine; Software; Standards; Anticubital; Fiji; Interactive GUI; ROI; Radiotracer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Advances in Computing, Communications and Informatics (ICACCI, 2014 International Conference on
Conference_Location :
New Delhi
Print_ISBN :
978-1-4799-3078-4
Type :
conf
DOI :
10.1109/ICACCI.2014.6968210
Filename :
6968210
Link To Document :
بازگشت