• DocumentCode
    1663496
  • Title

    Monitoring of retinic structure alterations by digital image analysis

  • Author

    Parodi, Maurizio Battaglia ; Giusto, Daniele D.

  • Author_Institution
    Eye Dept., Trieste Univ., Italy
  • fYear
    1989
  • Firstpage
    376
  • Abstract
    The usefulness of applying digital processing to eye-fundus images in order to obtain an accurate temporal monitoring of the pathology under examination is evaluated. In particular, an automatic segmentation algorithm that makes it possible to extract specific features for the pathology and then to characterize it in terms of dimensional parameters is presented. Some results for a case of type-2 Hayreh vasculity are reported and discussed
  • Keywords
    computerised monitoring; computerised picture processing; eye; medical computing; patient monitoring; automatic segmentation algorithm; digital image analysis; digital processing; dimensional parameters; eye-fundus images; monitoring; pathology; retinal structure alterations monitoring; type-2 Hayreh vasculity; Digital images; Hemorrhaging; Histograms; Image analysis; Image segmentation; Monitoring; Pathology; Performance analysis; Performance evaluation; Veins;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1989. Images of the Twenty-First Century., Proceedings of the Annual International Conference of the IEEE Engineering in
  • Conference_Location
    Seattle, WA
  • Type

    conf

  • DOI
    10.1109/IEMBS.1989.95778
  • Filename
    95778